News

Fall from edge protection system

April 19 2018

In March 2018, a 19 year old worker sustained fracture injuries to both kneecaps, partially severed fingers on one hand and a severe laceration to his calf when he fell approximately three metres from a roof.

An edge protection system was installed around the roof perimeter. The system was erected by a scaffolder and consisted of a post and rail setup. Scaffold components were used to construct the edge protections system, specifically tube and coupler. Early investigations indicate there may have been a failure of a mid-rail which the worker was leaning against. The mid-rail has pulled away on one end at the coupler joint, resulting in the worker falling through the gap.

The investigation is continuing.

Preventing a similar incident

Edge protection systems may be an effective way to manage some of the risks of working at heights. The effectiveness of an edge protection system depends on:

  • appropriate design
  • manufacture in accordance with the designer’s specifications
  • test and examination after manufacture
  • instructions supporting use and maintenance of the system
  • correct installation by a competent person
  • appropriate use.

If edge protection is used as a control measure, then section 306E of the Work Health and Safety Regulation 2011 also requires:

  • the design withstands the downwards or outwards force of the impact of a person falling against it
  • that a rail, or another component that prevents people from falling, be fitted
  • that another rail (or rails), or sturdy mesh, sheeting or other material below the rail or component be fitted.

If the edge protection has rails, the edge protection must have:

  • a bottom rail fitted at least 150mm, but not over 250mm, higher than the surface that is at the base of the edge protection; or
  • a toe board, for the surface that is at the base of the edge protection, at least 150mm high and fitted below all rails of the edge protection; and
  • another rail or rails fitted so that there is not over 450mm between any rail and its nearest rail or between the lowest rail and any toe board for the surface that is at the base of the edge protection; and
  • if the slope of the surface from which work is to be done is over 26° – sturdy mesh, sheeting or other material that extends upwards at least 900mm from the surface that is at the base of the edge protection or the toe board.

Read the full article here.

Other News

Fall from edge protection system

April 19 2018

In March 2018, a 19 year old worker sustained fracture injuries to both kneecaps, partially severed fingers on one hand and a severe laceration to his calf when he fell approximately …

Safety Alert: Falls through skylights and plastic roof sheeting

April 5 2018

Safework NSW has released a Safety Alert about Falls through skylights and plastic roof sheeting. This safety alert reminds persons of the risks associated with working on roofs with skylights or …

Worker killed in skylight fall

March 13 2018

n February 2018, a worker was killed after falling five metres onto a concrete floor. Early investigations indicate the worker was attending to a radio tower on the roof of a …

11 falls prompts warning about working safely at heights

February 14 2018

WorkSafe has warned there will be consequences for not managing the risk associated with working at heights on construction sites following two serious incidents in less than two weeks. A 19-year-old …

$150,000 fine after fall leaves worker a paraplegic

December 18 2017

A workplace incident in which a maintenance worker fell six metres and was left paraplegic has resulted in a $150,000 fine for the height safety company involved. The company, which pleaded …

New Guide for managing the risks of working in heat released by SafeWork Australia

December 8 2017

Heat is a hazard in many Australian workplaces, whether work is performed indoors or outdoors, so the guide has been produced to help employers and workers stay safe. People in control …